Skip to content

Converting small general object detecting models to lumen experts

License

Notifications You must be signed in to change notification settings

theveryhim/Lumen-Detection

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

14 Commits
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Lumen Detection

Lumen detection in colonoscopy images refers to the identification and location of the central region of the intestinal tract (lumens) in colonoscopy images. This is done to correct guidance, improve the quality of imaging, and It is very important to avoid navigational errors. Also, accurate detection of lumens can be effective in increasing the accuracy of lesion detection and improving the segmentation of polyps.

In this repo, we represent our work on colonoscopy images by light weight models as binary classifiers

*Due to confidentiality matters, we are unable to share data set directly here. If you need the acces contact any of us: * (Arman Yazdani)[]

SqueezeNet

We trained SqueezeNet v1.1 from scratch with a custom lightweight classification head:

  • Final classifier:
    Conv2D(512 → 32) → BatchNorm → ReLU → AdaptiveAvgPool2d → Linear(32 → 1)
  • Output is passed to BCEWithLogitsLoss for binary classification.
  • Trainable params: 739,009

Descriptive Alt Text

MobileNetV3small

We Fine-tuned MobileNetV3 Small, a lightweight convolutional neural network, pre-trained on ImageNet and fine-tuned for our binary classification task. Final layer adapted to output a single logit → Binary classification with BCEWithLogitsLoss

  • Model: MobileNet V3 small
  • Weights: Pretrained
  • Trainable params: 1,518,881
  • Loss Function: BCEWithLogitsLoss for binary output
  • Optimizer:
    • Adam optimizer with learning rate 1e-4
    • Learning rate scheduling using ReduceLROnPlateau
    • Early stopping based on validation loss

Descriptive Alt Text

Gradio UI 😊

We also prepaired a user friendly interface where you can uplaod your colonoscpy image or data set and see our models inference

Descriptive Alt Text

Here's how to use it on your local host:

git clone https://github.com/theveryhim/Lumen-Detection.git your-directory
cd ...\your-directory\Lumen-Detection
python app.py

then follow to the given link and tadaa!

Lumen detection+

Here we try to Improve our models to their best performance for lumen detection through systematic optimization and new training techniques. Further more, We focus on balancing accuracy with computational efficiency for practical deployment.

SqueezeNet

Let's continue with the smaller/faster model!

Hyperparameter Optimization: Ray

Used Ray Tune with ASHA scheduler for Bayesian optimization. Searched loguniform spaces for lr (1e-4 to 1e-1), weight_decay (1e-6 to 1e-2), and batch_size [16,32,64]. Maximized val_acc over 10 trials.

Descriptive Alt Text

Hyperparameter optimization with Ray

Training: Curriculum Learning

Our strategy combines a fixed curriculum of Progressive Data Deblurring with the MixUp regularization technique, executed using the previously optimized hyperparameters.

Descriptive Alt Text

Enahnced models performance

Production Prototype: ONNX

  • Exported optimized models to ONNX format for production deployment.

Descriptive Alt Text

ONNX/Enhanced models performance

Avg PyTorch inference time per batch: 98.930 ms
Avg ONNXRuntime inference time per batch: 20.431 ms
  • Employed quantization techniques for potential edge deployment scenarios.
PyTorch int8 inference time per batch (CPU): 103.658 ms
ONNX int8 inference time per batch: 55.911 ms
Evaluating models...
PyTorch INT8 Accuracy: 0.8627, F1_torch: 0.8574, AUC_torch: 0.8625
ONNX INT8 Accuracy: 0.8513, F1_onnx: 0.8465, AUC_onnx: 0.8513

MobileNetV3small

In this phase, we've done below tasks:

  1. Realistic colonoscopy-specific augmentations:
Augmentation Type Purpose
Geometric Simulate camera movements (flip, rotate, affine, zoom)
Photometric Adjust brightness, contrast, saturation, hue
Noise & Blur Simulate real-world motion blur and camera noise
  1. Systematic hyperparameter search for stable training:

    Used Ray Tune with ASHA scheduler for Bayesian optimization. BCE Loss:

    search_space = { "lr": tune.loguniform(1e-5, 1e-3), "batch_size": tune.choice([16, 32, 64]), "optimizer": tune.choice(["AdamW", "SGD"]), "weight_decay": tune.loguniform(1e-6, 1e-2), "momentum": tune.uniform(0.8, 0.99) }

    Focal Loss:

    search_space = { "gamma": tune.uniform(0.0, 4.0), "lr": tune.loguniform(1e-5, 1e-3), "weight_decay": tune.loguniform(1e-6, 1e-3), "batch_size": tune.choice([8, 16, 32]), "optimizer": tune.choice(["adam", "adamw", "sgd"]), "momentum": tune.uniform(0.5, 0.99)
    }

  2. Loss function comparison:

    BCE Loss – standard binary classification. Focal Loss (α=0.5) – emphasizes hard-to-classify samples.

  3. Hard example mining to focus on difficult cases.

The overall workflow:

image

Results: BCE vs. Focal Loss

The comparison was conducted over 20 training epochs with the same dataset, augmentation pipeline, and hyperparameter tuning workflow.

Hyperparameter BCE Best Value Focal Loss Best Value
Learning Rate 0.0002997 0.00003432
Weight Decay 5.16e-05 1.03e-04
Batch Size 16 16
Optimizer AdamW AdamW
Momentum
Focal Gamma 0.8724

Training and Validation Curves

Loss Curves: Focal Loss converges faster and achieves a lower final loss, indicating better handling of challenging samples.

Accuracy Curves: Both models surpassed 94% accuracy on validation data. Final accuracy was similar, suggesting that Focal Loss improves robustness rather than raw accuracy.

image

Classification Metrics on Test Set

Focal Loss matches BCE for lumen detection while focusing on hard cases, which is crucial in clinical settings.

Loss Function Accuracy Class Precision Recall F1-Score
BCE 0.94 lumen 0.93 0.95 0.94
no-lumen 0.95 0.95 0.94
Focal (α = 0.5) 0.94 lumen 0.93 0.95 0.94
no-lumen 0.95 0.92 0.93

Grad-CAM Visualization

Focal Loss encourages the model to attend to subtle, challenging features that are often missed by BCE.

image

Hard Example Evaluation

  1. Reduction of Dangerous Errors:

Focal Loss reduced high-confidence incorrect predictions by ~33%.

These are the most critical errors in medical imaging since the model is confident but wrong, which could mislead clinicians.

  1. Improved Calibration:

Focal Loss pushes predictions closer to the 0.5 boundary for uncertain cases.

This creates a well-calibrated model:

High confidence → usually correct

Low confidence → indicates uncertainty

BCE, by contrast, tends to overfit, producing overly confident predictions even when incorrect.

  1. Model "Knows What It Doesn't Know":

Focal Loss improves the model’s awareness of uncertainty, a hallmark of reliable AI in healthcare.

Hard Example Type BCE Focal Loss
Misclassified count 64 68
Low-confidence correct count 31 74
High-confidence incorrect count 33 22
Borderline count 88 175

A Bigger Stride: Knowledge Distillation

Leveraged MobileNetV3 teacher to enhance SqueezeNet student performance. Combined hard and soft loss for effective knowledge transfer.

Descriptive Alt Text

Student(SqueezeNet) model's performance after knowledge distillation

Test Accuracy: 0.8738, F1: 0.8501, AUC: 0.9291

About

Converting small general object detecting models to lumen experts

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published